这是链路中的一环,需先有容器内执行权限,单独利用价值有限。
参数注入iot容器cve
Philips Hue Bridge Pro Argument Injection Restricted File Write Vulnerability
November 6th, 2026
ZDI-26-890
ZDI-CAN-33090
CVE ID
CVE-2026-118631
CVSS Score
3.8
AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:L/A:N
Affected Vendors
Philips
Affected Products
Hue Bridge Pro
Vulnerability Details
This vulnerability allows local attackers to modify files on affected installations of Philips Hue Bridge Pro. An attacker must first obtain the ability to execute low-privileged code within a container on the target system, in order to exploit this vulnerability.
The specific flaw exists within the factory data service, which listens on TCP port 5001 by default. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to modify files in the context of the service account.
Additional Details
Fixed in Bridge Pro firmware version 6.1.2071524030 (or later)
https://www.philips-hue.com/en-ca/support/release-notes/bridge-pro
Disclosure Timeline
2026-08-27
- Vulnerability reported to vendor
2026-11-06
- Coordinated public release of advisory
2026-11-06
- Advisory Updated
Credit
Connor Ford @ByteInsight of TrendAI Zero Day Initiative
Back to Advisories